Mammography Skin Markers
|
Beekley invented the skin marking system for mammography. It
is used in thousands of hospitals and breast care centers
across the country to improve the quality of patient
care through clearer communication between technologists
and doctors. This system is a simple and effective way
to identify nipples, palpable masses, surgical scars
and raised moles.
|
Four distinctive shapes convey unmistakable
images on film, resulting in better communication and
fewer additional views, repeats, callbacks and questions.
For legal and documentation purposes, nothing can replace
the efficacy and permanence of skin markers. |
| Limited Edition Skin Markers |

2.5mm pellet |
 
Nipple Marker:
N-Free SPOTS® 2.5mm
order code: 532
contents per box: 110 |
| |
|
Lead-free, Latex-free,
Hypoallergenic.
|

see-through mole marker |
 
Mole Marker:
O-SPOTS® light image
order code: 552
contents per box: 58 |
see-through ring |
| |
|
Lead-free, Latex-free,
Hypoallergenic.
|

1.0mm diameter see-through scar marker
|


Scar Marker:
S-SPOTS® light image
order code: 550
contents per box: 327cm |
see-through line |
|
Lead-free, Latex-free,
Hypoallergenic.
|

radiopaque palpable mass marker |
 
Palpable Mass Marker:
A-SPOTS® opaque triangle
order code: 557
contents per box: 120 |
burnout-resistant radiopaque triangle |
| |
|
Lead-free, Latex-free,
Hypoallergenic.
|
IMPORTANT NOTE: All Beekley pellet products are lead-free for your safety and that of your patients!

1.5mm pellet |

N-SPOTS®
order code: 108
contents per box: 122 |
1.5mm pellet with adhesive side tabs |
|

X-SPOTS®
order code: 101
contents per box: 150 |
1.5mm pellet with easy pik-up™tab |
|
|

2.0mm pellet |

Y-SPOTS®
order code: 102
contents per box: 132 |
2.0mm pellet with easy pik-up™tab |
|
|
|

N-SPOTS®
order code: 110
contents per box: 122 |
2.0mm pellet with adhesive side tabs |
|

N-FREE SPOTS®
order code: 153
contents per box: 110 |
2.0mm pellet with adhesive-free center |
|
|

2.5mm burnout-resistant pellet |

V-SPOTS®
order code: 103
contents per box: 130 |
2.5mm burnout-resistant pellet with easy pik-up™tab |
|
|
|
|

N-FREE SPOTS®
order code: 132
contents per box: 110 |
2.5mm burnout-resistant pellet with adhesive-free center |
|

N-SPOTS® soft 'n stretchy®
order code: 190
contents per box: 94
|
2.5mm burnout-resistant pellet with pinch-free™suede-like material and adhesive-free center |
|
IMPORTANT NOTE: All Beekley pellet products are lead-free for your safety and that of your patients!
Beekley's new low-density, non-metallic nipple markers are perfect for digital mammography. The distinct 2.3mm round shape precisely and unmistakably documents the nipple's location on the image without artifact. Available in three popular nipple marker styles for your preference. |
|

NEW! Perfect for Digital!
Florals V-SPOTS®
order code: 703
contents per box: 130 |
2.3mm pellet with easy pik-up™tab |


NEW! Perfect for Digital!
Florals N-FREE soft 'n stretchy SPOTS ®
order code: 790
contents per box: 94
|
2.3mm pellet with pinch-free material and adhesive-free center |
|


NEW! Perfect for Digital!
Florals N-FREE SPOTS®
order code: 732
contents per box: 110 |
2.3mm pellet with adhesive-free center |
|
| |
|
|
|

1.5mm pellet |

Florals N-SPOTS®
order code: 608
contents per box: 122 |
1.5mm pellet with adhesive side tabs |
|

Florals X-SPOTS®
order code: 601
contents per box: 150 |
1.5mm pellet with easy pik-up™tab |
|
|

2.0mm pellet |
Florals Y-SPOTS®
order code: 602
contents per box: 132 |
2.0mm pellet with easy pik-up™tab |
|
Click for a close-up view of the patterns |
|

Florals N-SPOTS®
order code: 610
contents per box: 122 |
2.0mm pellet with adhesive side tabs |
|

Florals N-FREE SPOTS®
order code: 653
contents per box: 110 |
2.0mm pellet with adhesive-free center |
|
|

2.5mm burnout-resistant pellet |

Florals V-SPOTS®
order code: 603
contents per box: 130 |
2.5mm burnout-resistant pellet with easy pik-up™tab |
|
 |
|

Florals N-FREE SPOTS®
order code: 632
contents per box: 110 |
2.5mm burnout-resistant pellet with adhesive-free center |
|

Florals N-SPOTS®
soft 'n stretchy®
order code: 690
contents per box: 94 |
2.5mm burnout-resistant pellet with pinch-free™suede-like material and adhesive-free center |
|

see-through palpable mass marker
radiopaque palpable mass marker
|

A-SPOTS® light image™triangle
order code: 151
contents per box: 120 |
see-through palpable mass marker |
A-SPOTS® triangle
order code: 157
contents per box: 120
|
burnout-resistant radiopaque triangle |
|
|
| Florals Palpable Mass Markers |

see-through palpable mass marker
radiopaque palpable mass marker
|

A-SPOTS® light image™triangle
order code: 651
contents per box: 120 |
see-through palpable mass marker |
 
A-SPOTS® triangle
order code: 657
contents per box: 120
|
burnout-resistant radiopaque triangle |
|
Click for a close-up view of the patterns |
| Brochure / Sample Request |
Click Here to Request Sample
| Mammography SPOTS Product Pricing (includes Florals) |
| SPOTS |
1 - 4 boxes $98.00 |
5 - 9 boxes
$84.00 |
10 - 19 boxes
$80.00 |
20 - 49 boxes
$70.00 |
50 - 99 boxes
$53.50 |
100 + boxes
$37.00 |
 |
To
place your order, contact BEEKLEY today:
Tel: 1-800-BEEKLEY (233-5539) Fax:
1-800-735-1234 |
Back to top
| Mammography Product
Features & Benefits: |
New and Proven Technologies
In both the new digital and current film-screen mammography
modalities, skin marking benefits remain the same. For
legal and documentation purposes, nothing can replace
the efficacy and permanence of skin markers. It's still
all about enhanced communication, documentation and
accuracy in aiding in the early detection of breast
cancer.
ONLY FROM BEEKLEY: Light Image™(see-through) Markers

see-through palpable mass marker |

see-through scar marker |

see-through mole marker |
Only Beekley's see-through Light Image skin
markers "won't hide a cancer!" Our
exclusive low-density material will not obscure micro-calcifications
or any suspicious areas. That means better communication,
fewer questions and fewer additional views. Beekley
knows the only way to fight breast cancer is to expose
it.
Soft 'n Stretchy™Markers
Exclusive soft, suede-like, elastic material provides
maximum patient comfort under compression. Pinch-free
and pliable, Soft 'n Stretchy™products
stay securely in place and contour to the breast, bending
and expanding under compression throughout the exam.
And they lift off easily for painless removal.

N-SPOTS®
order code: 190
soft 'n stretchy
2.5mm nipple marker
|

S-SPOTS®
order code: 177
soft 'n stretchy
1.0mm see-through scar marker |

O-SPOTS®
order code: 191
soft 'n stretchy
see-through mole marker |
Digital Imaging Compatibility
Full Field Digital Mammography (FFDM) is an emerging
new technology using computers and specially designed
detectors to produce a digital image of the breast that
can be displayed on high resolution monitors. Clinical
feedback from our "digital" customers reinforces
that nipple marking, first and foremost, continues to
serve as a landmark for determining the exact location
of areas of concern. Mole, scar and mass marking serve
to locate, characterize and document any areas of interest
on the breast.

cc view of nipple marker |

mlo view of nipple, scar, mole marker |

mlo view of scar marker |

cc view of nipple and scar marker |
| Can You Spot the Nipple? - Interactive Challenge |
Can you spot the nipple? Take our interactive challenge.
| 21 Reasons Why Every Nipple Should Be Marked |
CLICK HERE to print your free poster!
"Sticks Just Right" Adhesive
Beekley markers stay on the patient 33% more
than other brands*. SPOTS® are made with unique
materials that flex with the patient. So, instead of
slipping out of place or ending up on the floor, they
stay where they are supposed to be for accurate, reliable
films the first time.
When your markers need to stick, Beekley';s stick
just right.
*Source: 2002-2003 Beekley Clinical Study.

patient with markers being applied |

patient under compression |
Back to top
| Clinical
Information & White Papers: |
Skin Marking Case Study (Analog)
This case involves a patient who had
an initial screening mammogram. An area of concern was
marked with a grease pencil by the Radiologist. This
was interpreted as a suspicious lesion and the patient
was subjected to a repeat exam.
Same patient repeated, but technologist
noticed a raised mole and marked it with a Beekley Light
Image O-SPOT mole marker. Conclusion: using a mole marker
the first time would have saved unnecessary additional
films, repeats, callbacks, time and most importantly,
patient anxiety.

suspicious lesion marked with grease pencil. (see yellow highlighted area above) |
|

mole re-imaged within marker clarifies "suspicious lesion" |
|
Routine use of Beekley O-shaped mole markers clarifies skin lesions that mimic pathology on mammograms.
Have you ever encountered a situation where a suspicious area showed up on a patient's film and you called the patient back for a diagnostic work-up....only to discover that the "suspicious area" was really a skin mole? On mammograms, moles frequently present problems when they appear to mimic a new mass and possibly even a cancer. Many mammographers note the presence of moles on the breast diagram, but this fails to take into consideration that the shape of the breast is altered by compression. Raised moles image about 10% of the time and you never know when they will. They often image on one view and may image one year and not the next. Marking can help clarify this issue. Learn more about mole marking by reading the case presentation here.
"Mammographic markers may lead to confusion and liability"
A malpractice article from March 2005's Diagnostic Imaging
Radiologists in a modern mammography practice are often confronted with marking devices that have been placed on a patient's breasts. These situations include cases of palpable abnormalities as well as skin lesions such as moles and even marking of prior biopsy sites. The type of mammographic marking device used is quite variable, and this lack of standardization may cause major difficulties in interpretation. Learn more about mammographic marking by reading the article here.
White Papers (Click to download the titles below)
PROPER POSITIONING WITH THE USE OF NIPPLE MARKERS
by Susan Sprinkle-Vincent, A.A.S., R.T. (R) (M) Mammography Program Manager and Consultant
Advanced Health Education Center, Houston, Texas
LOCALIZATION OF AN AREA OF CONCERN SEEN ON ONLY ONE VIEW IN MAMMOGRAPHY
by William R. Acker, M.D., Chairman and Medical Director - Medical Imaging
CIGNA Healthcare of Arizona
NIPPLE MARKING IMPROVES ACCURACY OF MAMMOGRAPHY
by William R. Acker, M.D., Chairman and Medical Director - Medical Imaging
CIGNA Healthcare of Arizona
BENEFITS OF ROUTINE NIPPLE MARKING IN MAMMOGRAPHY
by Deborah A. Berger, M.D., Radiologist, Physician Consultant
The Beekley Advantage:
Beekley SPOTS® are made with unique materials that flex with the patient,
so instead of shifting or moving, like you see here with other brands, they stay right on
the mark throughout the exam. For trustworthy films, the first time.
The following video clips are excerpts from the Beekley Educational Video.
We have provided two video formats for you to select from. Click on one
of the video icons to play the video. If you do not have the player, you
will be prompted to download it. Or you can download a player using these links:
Windows
Media Player and
QuickTime
Watch the Beekley Knuckle Adhesive Test
Beekley SPOTS are made with a high-quality, medical grade adhesive and unique materials that flex with the patient. So, instead of shifting or moving like other brands, they stay on the mark throughout the exam. Try this comparison test yourself and feel the Beekley Difference. We're confident that in the final analysis, you'll stick with Beekley!
Beekley Light Image SPOTS®:
|
How Light Image SPOTS® communicate
on film, Dr. Koblick
Lawrence and Memorial Hospital, CT
|
(584k)
(411k) |
Discussion of different shapes of
Light Image SPOTS® on film, Dr. Stelling
MD Anderson Cancer Center, TX
|
(1,115k)
(791k) |
Use of Light Image O-SPOTS®
on a patient with multiple moles, Dr. Koblick
Lawrence and Memorial Hospital, CT
|
(1,903k)
(1,361k) |
Beekley S-SPOTS®:
|
Importance of using S-SPOTS®
on a post-surgical breast, Dr. Birdwell
Stanford University Medical Center, CA
|
(927k)
(663k) |
Case discussion of Light Image S-SPOTS®,
Dr. Ikeda
Stanford University Medical Center, CA
|
(2,597k)
(1,858k) |
Importance of S-SPOTS® in discovery
of early recurrent cancer, Dr. Giess
Nyack Hospital Women's Diagnostic and Wellness Center, NY
|
(1,764k)
(1,110k) |
Summary of benefits from routine
Beekley S-SPOTS® use.
|
(1,544k)
(1,100k) |
Back to top
| FREE! Importance of Good Compression Plaque Poster |
Beekley Corporation is offering a complimentary petite poster (8.5" x 11") that speaks to your patients on why your facility puts patient care first by marking.
We suggest framing the poster to hang in your dressing rooms or waiting areas.
- Let us work together to" Mark" the Difference! |
CLICK HERE to print your free poster!
CLICK HERE to print last year's free poster!
|
Having trouble opening the image? You'll need Adobe Acrobat Reader,
a free download.
Click the Acrobat icon to the right. |
|
 |
Back to top
|